Desktop|中文
Home About Us
Products +
Company News Industry Trends Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

220V 3CM Fiberglass Electric Heating Tape 200

Published: 2026-08-13

Views: 2922

Category: Heating Cable

Product Description

220V 3CM fiberglass electric heating tape 200

Electric heating tape 200℃ insulation high temperature resistant 2-core 4-core for pipeline laboratory use The keywords you entered, "220V 3CM fiberglass electric heating tape 200℃ insulation high temperature resistant 2-core 4-core pipeline laboratory use," are a set of very professional industrial and laboratory heating consumables. This type of product is mainly used for uniform heating, heat preservation, or process temperature maintenance of metal pipes, glassware, or valves.

Based on your parameter requirements, I have organized the core technical characteristics, selection points, and safety usage specifications of this series of fiberglass heating tapes:

1. Core materials and temperature resistance characteristics

Heating element: Usually uses nickel-chromium alloy strip or alloy electric heating wire as the heating body, featuring fast heating, high thermal efficiency, and good oxidation resistance.

Insulation and sheath: Multi-layer alkali-free fiberglass braiding is used as insulation and outer covering material. This inorganic material not only withstands high temperatures (conventionally up to 200℃, with some high-end models reaching up to 450℃) but is also wear-resistant and tensile, with no abnormalities in over 25,000 flexing tests.

Specification matching: The "3CM" you mentioned refers to a width of 30mm, which is a common industrial wide specification, suitable for larger pipe diameters or scenarios requiring large-area heating.

2. Core count selection (2-core vs 4-core)

In a 220V power supply system, the choice of core count directly affects the wiring method:

2-core heating tape: Internally contains two parallel wires (one live wire, one neutral wire). Suitable for direct single-phase 220V power supply. Installation only requires connecting the two ends to the power source, suitable for heating shorter pipe lengths.

4-core heating tape: Usually contains two independent heating circuits internally. This design allows for segmented control in long-distance pipe heating, or balancing three-phase loads under specific wiring methods, providing more flexible temperature zone control.

3. Laboratory and pipeline application specifications

Glassware heating: When used on glass systems (such as flasks, condensers) in the laboratory, it is strictly prohibited to directly attach the heating tape to the glass. A 1-2 layer aluminum foil must be placed between the heating tape and the glass to prevent local overheating causing glass cracking, while the aluminum foil also serves to conduct heat evenly.

Metal pipe heating: Can be directly wrapped around the metal pipe surface. To further increase heating temperature and reduce heat loss, it is recommended to wrap another layer of aluminum foil or insulation cotton on the outside of the heating tape.

Installation prohibitions: Fiberglass heating tapes must never be crossed or overlapped during installation. Overlapping can prevent heat dissipation, causing severe local overheating, which can burn out the heating tape or even cause a fire.

4. Safety and moisture-proof precautions

Non-moisture-proof design: Standard fiberglass heating tapes typically do not have waterproof or moisture-proof functions (non-moisture-proof products). Once damp, the insulation resistance will drop significantly. Ensure it is thoroughly dried before powering on.

Temperature control requirements: Although the heating tape itself can withstand temperatures above 200℃, to precisely control process temperature and prevent dry burning, it is strongly recommended to use a temperature controller (such as thermocouple + PID temperature control box) for precise temperature control.

💡 Further assistance


Fiberglass heating tapes are flexible heating products with a high degree of customization. May I ask what your specific needs are currently:

Parameter calculation and customization: Do you need me to calculate the total power (W/m) and total length of the heating tape required based on the pipe length, diameter, and target temperature?

Wiring and temperature control solutions: Do you need me to provide wiring diagrams for 2-core/4-core heating tapes under 220V, or recommend matching temperature controller models?

Selection comparison: Do you need a comparison of the advantages, disadvantages, and applicability of fiberglass heating tapes versus the "silicone rubber heating jacket" you previously considered in laboratory scenarios?

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us